Products

  • HOME
  • Products
  • Pressure

APT3100

Function

  • Type
  • Pressure: Differential(DPIT), Gauge/ Absolute(PIT),
    Level(LIT), High Static Pressure, Flow Pressure(FIT)
  • Certificate
  • SIL2 (TUV, FMEDA), Ex d, Ex ia, FM, ATEX, TR
    CU(EAC), INMETRO, CE, Rohs, BV, LR, KR, DNV, ABS,
    KCs, IP66/67, NEMA 4X
  • Feature
  • 4 to 20mA, HART, Loop Powered

    Accuracy ± 0.075% (option ± 0.04%) of CS*

    3 lines LCD display, Self Diagnostic Function, External Buttons, DAC, Zero Trim, Eng mode
  • Application
  • Pressure, Flow, Level measurement for Oil & Gas, Liquid, Water, Maine & offshore, Vessel, Power, Chemical Plants and Refinary

Type and Specifications

  • Model TypeAPT3100-G Guage pressure
  • Sensor RangeMin -100 to Max 41,370 kPa
  • Calibrated SpanMin 0.075 to Max 41,370 kPa
  • Max. Working PressureMax 75 MPa / 10,878 psi
  • AdvantageLow pressure gauge measurement
  • Model TypeAPT3100-A Absolute pressure
  • Sensor RangeMin 0 to Max 2,500 kPa(A)
  • Calibrated SpanMin 2.5 to Max 2,500 kPa(A)
  • Max. Working PressureMax 5.25 MPa / 761 psi
  • AdvantageAbsolute pressure measurement
  • Model TypeAPT3100-D Differential pressure
  • Sensor RangeMin 0 to Max 6,895 kPa
  • Calibrated SpanMin 0.075 to Max 6,895 kPa
  • Max. Working Pressure13.79 MPa / 2,000 psi
  • AdvantageDifferential, Flow & Level measurement
  • Model TypeAPT3100-H High Static pressure
  • Sensor RangeMin 0 to Max 2,068 kPa
  • Calibrated SpanMin 0.373 kPa to Max 2,068 kPa
  • Max. Working Pressure31.02 MPa / 4,525 psi
  • AdvantageHigh static pressure measurement
  • Model TypeAPT3100- / -MP Multi-planar
  • Sensor RangeMin 0 to Max 6,895 KPa
  • Calibrated SpanMin 0.075 to Max 6,895 KPa
  • Max. Working Pressure31.02 MPa / 4,525 psi (75 Mpa for GP)
  • Advantage3 process connections including bottom direction
  • Model TypeAPT3100-F
  • Sensor RangeMin 0 to Max 6,895 KPa
  • Calibrated SpanMin 0.075 to Max 6,895 KPa
  • Max. Working Pressure13.79 MPa / 2000 psi
  • AdvantageFlow Totalizing, Additional 2 wires for Pulse output to relay/counte
  • Model TypeAPT3100-D-ST
  • Sensor RangeMin 0 to Max 6,895 KPa
  • Calibrated SpanMin 0.075 to Max 6,895 KPa
  • Max. Working Pressure13.79 MPa / 2000 psi
  • AdvantageFlow Totalizing, Additional 2 wires for Pulse output to relay/counter
  • Model NameModel Name //Protocol//Trim ability //Power supply & Load Requirement //Falure Mode //External Buttons //Process Temp. limit //Range Abilitiy //Stability
  • ProtocolAPT3100//4 to 20mA + Digital Communication, HART 5//Zero, DAC, FULL//250 to 550 ohm @ 24 Vdc, Loop Powered//Low ≤ 3.78 mA, High ≥ 21.1 mA//Zero & Span 2 buttons for device configuration//-40 to 120℃ ( -104 to 248℉ )//100:1//±0.125% URL for 36 months
  • Trim ability
  • Power supply & Load Requirement250 to 550 ohm @ 24 Vdc, Loop Powered
  • Falure ModeLow ≤ 3.78 mA, High ≥ 21.1 mA
  • External ButtonsZero & Span 2 buttons for device configuration
  • Process Temp. limit-40 to 120℃ ( -104 to 248℉ )
  • Range Abilitiy100:1
  • Stability±0.125% URL for 36 months

APT3100 Catalogue

DOWNLOAD

APT3100 Manual (KR)

DOWNLOAD

APT3100 Manual (EN)

DOWNLOAD

APT3100-D OUTLINE Drawing

DOWNLOAD

APT3100-D-MP OUTLINE Drawing

DOWNLOAD

APT3100-G OUTLINE Drawing

DOWNLOAD

APT3100-H OUTLINE Drawing

DOWNLOAD

APT3100 Bracket Assembling

DOWNLOAD

APT3100 2 Way Integral Manifold Assembling

DOWNLOAD

APT3100 3 Way Integral Manifold Assembling

DOWNLOAD

APT3100 5 Way Integral Manifold Assembling

DOWNLOAD